ROOFSEAL membrane is ideal for a wide
range of waterproofing applications including roofs, basements, tunnels,
car parks and resevoirs.
 
Total
impermiability.
Good
bondability & seam integrity.
Stability
at high temperature.
Good
performance at a broad temperature range.
Good
flexibility.
Compatible
with all normal roofing and building components.
 
ROOFSEAL is installed by torch welding method, loose-laid
or fully bonded to substrate. When loose-laid, only laps are bonded
together. Peripheries and protrusions are sealed according to
specifications.
 
The underside of the membrane should be
torched just enough to superficially melt the bitumen. Excessive heating
may damage the reinforcement. Overlaps should be reheated from the top
and resealed with a trowel to ensure seam integrity.
|
 ROOFSEAL
is available in two basic finishes:
Black smooth finish
with polyethylene surfaces for covered pplications.
Granule surfacing for
exposed applications.

|
For flat areas
|
1 mt.1.13 M2/M2
per layer
|
|
For 30 cm. girth flashing
|
0.35
M2/Mt/ length
|
|
Average wastage
|
3 - 5%
|
 
ROOFSEAL complies with the tolerance
levels of ASTM and UEAtc standards.
 
In
addition to stringent regular tests by BITUMAT laboratory, our products
are tested periodically by Bureau Veritas & SOCOTEC, Paris,
France.
 
| Roll Length |
10mts |
| Roll width |
1 Mt. |
| Thickness |
3, 4 mm |
 
Gas torch, Knife, Trowel, Measuring tape, Marking string,
Gloves.
|
 |
 |
 |
 |
| Softening point 0C |
150 |
150 |
ASTM D-36 |
| Penetration, @ 250C, dmm+_2 |
20 |
20 |
ASTM D-5 |
| Tensile
Strength L/T, N/5CM @ 23 oC +2 |
650/450 |
350/300 |
ASTM D-5147 |
| Elongation
L/T, N/5CM @ 23 oC +2 |
40/45 |
3.0/3.3 |
ASTM D-5147 |
| Tear Strength, N |
300/250 |
60/80 |
ASTM D-5147 |
| Heat
Resistance @ 80 oC +2 |
No
flow |
No
flow |
ASTM D-5147 |
| Cold
Flexibility oC +2 |
0-(-2) |
0-(-2) |
ASTM D-5147 |
| Lap
Joint Strength L/T, N/5CM @ 23 oC +2 |
650/450 |
350/300 |
CGSB-37-6P56M |
The information given in this Technical Sheet is to the best of our knowledge based on
laboratory tests and practical experience. However, as the product is often used under conditions beyond our control, we cannot guarantee but the product itself.
|